THE EFFECT OF LAYOUT OF ENERGY DISSIPATORS ON ENERGY DISSIPATE


Author(s): Serife Yurdagül KUMCU1, Kamil ISPIR2
  • 1. Necmettin Erbakan University, Faculty of Engineering and Architecture, Department of Environmental Engineering, Konya, Turkey
  • 2. State Hydraulic Works, 4. Regional Directorate, Konya, Turkey

Abstract: Energy dissipater in the stilling basin is a structure designed to protect downstream of the spillway from erosion and scour by reducing flow energy in the energy dissipation pool. Energy dissipation pool is an important element of hydraulic structures as a transition between the high-velocity flow and the sensitive tailwater. The aim of this study is to investigate the energy dissipation ratios of baffle blocks which constructed in Type III stilling basin with different geometric shapes by using physical and numerical modeling methods. Energy dissipation ratio of the baffle blocks were determined in 3 different layouts as single row, two rows and two rows without threshold structure for 7 different flow rates are tested. In addition, these experimental studies were tested in the FLOW-3D software program, and the results of experimental and numerical studies were compared. As a result of the study, it was determined that the results obtained from the experimental studies and the FLOW-3D software were similar to each other.